![]() ![]() Likewise, the fob has a red and green LED that provides the status for the enrollment into the control panel, status for arming, disarming, alarm, low battery (no LED) and RF transmission. The SiXFOB has a built-in piezo sounder for confirmation of arm, disarm, enrollment, or alarm conditions. Press and hold all four keyfob buttons for 5 seconds at once, immediately after starting the update. ![]() When performing a SiXFOB firmware update, it requires the user to press a button to activate the fob. The Honeywell Home SiXFOB is flash upgradeable and can be upgraded via the control panel in the Master Tools "Advanced" screen. Then, just press the top two buttons again to complete the enrollment. When ready to receive the SiXFOB transmitter's information on the KEYS enrollment screen of the controller, press the top two buttons together for about two seconds to cause the transmitter to register it. Each SiXFOB device has a unique MAC number located on the sticker on the unit.Īuto-enrollment of the SiXFOB to a SiX-Series compatible panel is a breeze. Due to its SiX-Series Sensor Lock feature, once enrolled, the SiXFOB keyfob cannot be used with another panel until it is removed from the current controller. When setting up, please remember to enroll and update the SiXFOB firmware (via the Control Panel) to ensure the latest version is being used. In a matter of minutes, the SiXFOB can be programmed and enrolled into the Lyric Controller (LCP500-L) or Lyric Controller Canada (LCP500-LC) all-in-one wireless touchscreen control panel. Be careful not to bend the wireless transmitter's antenna while removing or installing a battery.The Honeywell Home SiXFOB is a wireless, 4-button, encrypted remote alarm keyfob intended for use with control panels that support SiX-Series devices. Simply remove the (2) cover screws to get inside the 5869 to replace the battery. The 5869 will send a low battery trouble signal when the battery if almost dead. The commercial panic button is powered by one 3V lithium battery. If you are experiencing RF supervision troubles, you should either relocate your Honeywell 5869 commercial panic button or you should add a Honeywell 5800RP wireless repeater between the security system and the 5869. If the 5869, is out of range a RF supervision trouble signal will be activated until the device is seen by the wireless security system. The nominal wireless range of the 5869 wireless panic switch is 200' back to the wireless security system. ![]() You should not install the 5869 under metal counters or desks as it will reduce the panic button's wireless range. Another tamper can be triggered if the 5869 is forcibly removed from its mounting surface. One tamper will be triggered if the cover of the holdup switch is removed. The Honeywell 5869 has (2) separate tamper switches. The panic switch is then ready to trip another panic alarm. Once the holdup switch has been activated, you must use the included reset key to restore the 5869. However, you may program the holdup switch with whichever response type suits your application. Typically the 5869 wireless transmitter is programmed as a 24 hour silent zone type so that the central monitoring station can send the police immediately without the intruder being tipped off with a local alarm. With the 5869 panic button mounted under a counter or desk, the employee simply sticks his or her finger in the hole and pulls forward to activate a panic alarm even when your security system is disarmed. Protect your employees by providing them with a discreet way to signal a panic alarm. The 5869 works great as a holdup button for underneath a desk or cash register. The Honeywell 5869 is a wireless commercial panic switch. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |